Unit Size |
Volts
|
Phase
|
Compressor |
Total FLA |
Source Pump Fuse |
Branch Circuit Selection Current |
Load Pump Fuse |
Max Fuse (HACR) |
|
|
DWH0181CUVX |
208/230 |
1 |
7.4 |
48.0 |
7.4 |
5A |
13.0 |
5A |
20 |
|
Entering Source Temp |
Entering Load Temp |
Source GPM |
Load GPM |
Total Water Heating
Capacity BTU |
Heat of Absorption |
Total Heat Pump |
C.O.P. |
|
32 |
101 |
3 |
5.5 |
27,552 |
23,090 |
1304 |
6.1 |
|
40 |
69 |
3 |
5.5 |
27,700 |
22,571 |
1190 |
6.8 |
|
45 |
122 |
3 |
5.5 |
27,797 |
23,071 |
1386 |
6.5 |
|
50 |
121 |
3 |
5.5 |
29,999 |
24,262 |
1680 |
5.2 |